Test table - Display group 000 > < Measured value blocks, display groups 000...009
Display group 000 in idle (coolant temperature not below +80°C)
   
Display group 000 in idle (coolant temperature not below +80°C)
Display fieldDisplayed specified valueCorresponds to measured valueDenomination
1180...21080...110°CCoolant temperature (Precondition for basic setting)
214...3910...30%Engine load (without consumers)
370...82700...820 rpmEngine speed (without consumers)
4142...20610...14.5 VBattery voltage
51...100,4...4,0 %Throttle valve angle
6106...189-4,3...12.2%Load (moment) at idling speed
7113...143-3...+3%Initialisation value idling air mass
8115...141-10...+10%Control value of the fuel preparation (lambda control value) (if outside tolerance, perform test drive)
978...178-10...+10 %Initialisation value of the fuel preparation (lambda initialisation value) (if outside tolerance, perform test drive)
10103...153-10...+10%Initialisation value of the fuel preparation (lambda initialisation value) multiplicative (if outside tolerance, perform test drive)

   