Octavia Mk1
Display group 115 - Charge pressure control |
| |||||||||
Reading measured value block 115 | → | ← Readout on display | |||||||
xxxx rpm | xxx % | xxx mbar | xxx mbar | ||||||
1 | 2 | 3 | 4 | ← Display fields | Specification | Analysis | |||
Charge pressure - momentary value | Ambient pressure ...2200 mbar | — | |||||||
Charge pressure - specified value | Ambient pressure ...2200 mbar | — | |||||||
Engine load | 10...150 % | — | |||||||
Engine speed | 700...6800 rpm | — |