Properties of the self-diagnosis |
The control unit -J220- for the injection and ignition system Motronic is equipped with a fault memory. The fault memory is designed as a permanent memory and as a volatile memory. |
If malfunctions occur in the monitored sensors or components, they are stored in the fault memory with indication of the fault type. |
After it has analysed the information the engine control unit has different faults → Chapter between 67 to choose from, which are then stored until the fault memory contents are erased. |
Faults which occur only occasionally (sporadically), are marked as “sporadically occurring faults” with the suffix “/SP”. Possible causes of sporadic faults are e.g. a loose contact or a momentary line interruption. If a sporadic fault no longer occurs after 50 engine starts, it is erased from the fault memory. |
The stored faults can be read out with vehicle system tester -V.A.G 1552- or fault read-out scan tool - V.A.G 1551- → Chapter. |
After the fault(s) has(have) been removed the fault memory must be erased → Chapter. |
Note t
| The following description applies only for vehicle system tester -V.A.G 1552- used in combination with program card version 5.0. |
t
| If “Info in literature” appears in the display, look for the text required in the fault table under the fault code. |
t
| The use of fault read-out scan tool -V.A.G 1551 - (with program card version 8.0) with integrated printer is similar. A minor deviation on the display read-out is possible. |
|
|
|