Self-diagnosis IV > < Work step 10:2. Test of exhaust gas recirculation
Work step 11: Interrogating fault memory
Work step 11: Interrogating fault memory
–  Enter function 02“Interrogate fault memory” and confirm with Q.
   
The number of stored faults or “No fault recognised” appears in the display.
If a fault is stored in the memory:
–  Rectify the faults by referring to the fault table → Chapter 01-2 and generate readiness code again → Chapter.
If no fault is stored:
–  Press .
 
X faults detected                     →
Readiness code was successfully generated, if no fault is stored after repeating the test procedure in the fault memory of the engine control unit and if the following appears in the channel 017.
 
Reading measured value block         17   ->
00000000  00000110  10000000    00000000