Octavia Mk1
Display group 011 under full load (test drive in 2nd gear coolant temperature not below 75°C) |
Read measured value block 11 → | [lt ] Readout on display | ||||||
xxx rpm | xxxx mbar | xxxx mbar | xxx % | ||||
1 | 2 | 3 | 4 | [lt ] Display field | Specification | Analysis | |
On/off ratio of solenoid valve for charge pressure control -N75- | 55...80 % | → Chapter | |||||
Charge pressure (actual) | 1850...2250 mbar | → Chapter | |||||
Charge pressure (nominal) | 1900...2100 mbar | --- | |||||
Engine speed | 2800...3200 rpm | --- |