| Connect the hand vacuum pump e. g. -V.A.G 1390- to the vacuum unit |
–
| Actuate the hand vacuum pump and observe if the actuator rod for the charge air pressure regulating valve moves. |
If the actuator rod for the charge air pressure regulating valve does not move, the exhaust turbocharger must be replaced → Chapter. |
|
|
|