Test conditions > < Erasing fault memory
Actuator diagnosis
Actuator diagnosis
With the actuator diagnosis the following parts are activated in the sequence indicated:
1 - Exhaust gas recirculation valve - N18-
2 - AC compressor engagement
3 - Solenoid valve for charge pressure control -N75 -
4 - Changeover valve for intake manifold flap -N239 -
5 - Glow period warning lamp -K29 -
6 - Radiator fan control
7 - Glow plug relay -J52-
8 - Low heat output relay -J359-
9 - High heat output relay -J360 -
10 - Fault lamp
  Note
t  Actuation of the individual control elements is limited to 30 seconds.
t  If final control diagnosis is to be repeated wirthout starting the engine in-between, switch ignition off for about 20 seconds.
Special tools and workshop equipment required
t  Vehicle system tester -V.A.G 1552- with cable -V.A.G 1551/3, 3A, 3B oder 3C-
   

Test conditions > < Erasing fault memory