| Detach coolant hose from connection fitting -2-. |
–
| Unscrew bolts -1- and take off connection fitting -2- together with O-ring -3- and thermostat -4-. |
–
| Turn coolant regulator 1/4 turn (90°) and detach from connection fitting. |
–
| Clean sealing surface for O-ring. |
–
| Replace O-ring and moisten with coolant. |
–
| Insert coolant thermostat into the connection fitting and turn 1/4 turn (90°) to the right. Check: The clamp of the coolant thermostat must be positioned virtually vertical. |
–
| Tighten screws -1- to 15 Nm. |
Testing coolant thermostat |
–
| Heat up regulator in a water bath. |
|
|
|