Testing mechanical exhaust gas recirculation valve |
Special tools and workshop equipment required |
t
| Hand vacuum pump (e.g. -V.A.G 1390-) |
–
| Detach air guide pipe between inlet connection and charge air cooler from inlet connection. |
–
| Disconnect vacuum hose from mechanical exhaust-gas recirculation valve. |
|
|
|