Octavia Mk1
|
Reading measured value block | 0 | → | ← Read-out on display | ||||||||||
42 | 61 | 0 | 24 | 19 | 201 | 70 | 161 | 127 | 255 | ||||
Inducted air mass: ignore | |||||||||||||
Fuel temperature: no specified value | |||||||||||||
Intake manifold temperature: no specified value | |||||||||||||
Coolant temperature: 80...51 o.k.
| |||||||||||||
Ambient air pressure: ignore | |||||||||||||
Charge pressure: ignore | |||||||||||||
Injection rate: 15...45 o.k.
| |||||||||||||
Accelerator pedal position: 0 | |||||||||||||
Commencement of injection: 0...88 o.k.
| |||||||||||||
Idling speed: 41...44 o.k.
|
|
Reading measured value block | 0 | → | ← Read-out on display | ||||||||||
42 | 61 | 0 | 24 | 19 | 201 | 70 | 161 | 127 | 255 | ||||
Inducted air mass: ignore | |||||||||||||
Fuel temperature: no specified value | |||||||||||||
Intake manifold temperature: no specified value | |||||||||||||
Coolant temperature: 80...51 o.k.
| |||||||||||||
Ambient air pressure: ignore | |||||||||||||
Charge pressure: ignore | |||||||||||||
Injection rate: 15...45 o.k.
| |||||||||||||
Accelerator pedal position: 0 | |||||||||||||
Commencement of injection: 25...125 o.k.
| |||||||||||||
Idling speed: 41...45 o.k.
|
|
Read measured value block 1 → | ← Read-out on display | |||||||||||||||||||
900 rpm | 4.6 mg/s | 1.680 V | 87.3 °C | |||||||||||||||||
Coolant temperature
| ||||||||||||||||||||
Voltage of modulating piston movement sender -G149-
| ||||||||||||||||||||
Injection rate
| ||||||||||||||||||||
Engine speed
|
|
Read measured value block 1 → | ← Read-out on display | |||||||||||||||||||
900 rpm | 4.6 mg/s | 1.680 V | 87.3 °C | |||||||||||||||||
Coolant temperature
| ||||||||||||||||||||
Voltage of modulating piston movement sender -G149-
| ||||||||||||||||||||
Injection rate
| ||||||||||||||||||||
Engine speed
|
|
Read measured value block 2 → | ← Read-out on display | |||||||||
900 rpm | 0.0 % | 0 1 0 | 88.4 °C | |||||||
Coolant temperature
| ||||||||||
Operating position → Anchor | ||||||||||
Accelerator pedal position
| ||||||||||
Engine speed
|
|
Meaning, if display positions = 1 | |||||||||
x | x | x | Engine operating condition | ||||||
1 | Signal of air conditioning system - switch off air conditioning system | ||||||||
1 | o.k.: (Idling switch closed) | ||||||||
1 | Idling speed increases:
|
|
Read measured value block 3 → | ← Read-out on display | |||||||
900 rpm | 94 % | |||||||
On/off ratio (actuation) of exhaust gas recirculation valve
| ||||||||
No display | ||||||||
No display | ||||||||
Engine speed
|
|
Read measured value block 4 → | ← Read-out on display | |||||||||||||||||||||
900 rpm | 0.9° b.TDC | 0.9° b.TDC | 5 % | |||||||||||||||||||
On/off ratio (actuation) of commencement of injection valve
| ||||||||||||||||||||||
Momentary commencement of injection
| ||||||||||||||||||||||
The nominal injection commencement pumped by the control unit
| ||||||||||||||||||||||
Engine speed
|
|
Read measured value block 4 → | ← Read-out on display | |||||||||||||||||||||
900 rpm | 0.9° b.TDC | 0.9° b.TDC | 3 % | |||||||||||||||||||
On/off ratio (actuation) of commencement of injection valve
| ||||||||||||||||||||||
Momentary commencement of injection
| ||||||||||||||||||||||
The nominal injection commencement pumped by the control unit
| ||||||||||||||||||||||
Engine speed
|
|
Read measured value block 6 → | ← Read-out on display | |||||
0 km/h | 000 | 000000 | 255 | |||
CCS Operating condition 1) | ||||||
Operating condition of the cruise control system 1) | ||||||
Brake pedal monitoring → Anchor | ||||||
Vehicle speed: ignore |
1) Not yet available. |
|
Display field 2 | Operating condition of the clutch pedal and brake pedal | X | X | X | Operating condition of the pedal switch at display positions = 1 |
000 | Clutch pedal and brake pedal not pressed | 1 | Brake light switch -F - closed | ||
011 | Brake pressed (brake light switch) | ||||
011 | Brake pedal depressed (brake pedal switch) | 1 | Brake pedal switch -F47- open | ||
100 | Clutch pedal depressed | 1 | Clutch pedal switch -F36- open | ||
111 | Clutch pedal and brake pedal pressed |
|
Read measured value block 7 → | ← Read-out on display | |||||||
15.4 °C | 15.9 °C | 16.7 °C | ||||||
Coolant temperature (at coolant temperature sender -G62-)
| ||||||||
Intake manifold temperature (at intake manifold temperature sender -G72-)
| ||||||||
No display | ||||||||
Fuel temperature (at fuel temperature sender -G81-)
|
Note
|
Read measured value block 13 → | ← Read-out on display | |||||||||||
0.82 mg/s | -0.12 mg/s | 0.49 mg/s | ||||||||||
no display | ||||||||||||
Injection rate deviation of cylinder 4, 2, 1 to cylinder 3
| ||||||||||||
Injection rate deviation of cylinder 1 to cylinder 3
| ||||||||||||
Injection rate deviation of cylinder 2 to cylinder 3
| ||||||||||||
Injection rate deviation of cylinder 4 to cylinder 3
|
|
Read measured value block 13 → | ← Read-out on display | |||||||||||
0.82 mg/s | -0.12 mg/s | 0.49 mg/s | -0.12 mg/s | |||||||||
Smooth running control - injected quantity cylinder 4
| ||||||||||||
Smooth running control - injected quantity cylinder 3
| ||||||||||||
Smooth running control - injected quantity cylinder 2
| ||||||||||||
Smooth running control - injected quantity cylinder 1
|
|
Read measured value block 16 → | ← Read-out on display | |||||
70.0 % | 10000001 | 00 | 13.8 V | |||
Supply voltage of the control unit: ignore | ||||||
Heating element control → Anchor | ||||||
Operating condition of the additional heating → Anchor | ||||||
Generator capacity: ignore |
|
Meaning, if display positions = 1 | ||||||||
X | X | X | X | X | X | X | X | Additional heating deactivated, because: |
1 | Coolant temperature greater than 70...80°C1) or intake air temperature greater than 5°C | |||||||
1 | Generator defective | |||||||
1 | Battery voltage below 9 V | |||||||
1 | Engine speed less than 800 rpm | |||||||
1 | Engine start within the last 10 seconds | |||||||
1 | Coolant temperature sender -G62- or intake manifold temperature sender -G72- defective | |||||||
1 | Ignore | |||||||
1 | Ignore |
Meaning, if display positions = 1 | ||
X | X | Heating element control |
1 | Low heat output relay -J359-, switched on | |
1 | High heat output relay -J360 -, switched on |
|
Read measured value block 19 → | ← Read-out on display | |||||||||||||
0.780 V | 4.150 V | |||||||||||||
No display | ||||||||||||||
No display | ||||||||||||||
Voltage of modulating piston movement sender at maximum limit of metering adjuster
| ||||||||||||||
Voltage of modulating piston movement sender at minimum limit of metering mechanism
|
|
Read measured value block 19 → | ← Read-out on display | |||||||||||||
0.780 V | 4.150 V | |||||||||||||
no display | ||||||||||||||
no display | ||||||||||||||
Voltage of modulating piston movement sender at maximum limit of metering mechanism
| ||||||||||||||
Voltage of modulating piston movement sender at minimum limit of metering mechanism
|