skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Input values when changing the dash panel insert > < Adjustment
Adapt service interval display - SID
Adapt service interval display - SID
The service interval display must be adapted after replacing the dash panel insert.
Adjustment table:
   
Adaptation
channel:
Counter contents:
10Distance driven
in 1000 km
11Distance driven
in 1000 km
12Time in steps of 10 days

  Note
t  The entry of the relevant adaptation value for the distance counters can only be made in steps of 1000 km; consequently the read-out in the display is also in 1000 km.
t  The adaptation value must be entered as a 5-digit number (e.g. 00015 for adaptation value 15, equals a distance of 15000 km to the next service event).
t  The value entered is counted back to 0 km.
t  The time counter for the "SERVICE INSP" can be adapted with a maximum of 365 days.
t  Only a direct entry is possible using the keypad of the vehicle system tester!
t  If an incorrect value is entered the “Adaptation” function is terminated and it is then necessary to recommence!
SIA residual value for oil service
The number of km which are left to drive before the next oil change is required, can be entered with this channel if the dash panel insert is replaced.
–  Enter 10 (channel number).
–  Confirm the entry with key Q.
   
Readout on display:
The remaining kilometres until the next OIL service are displayed (1 is still 1000 km in our example).
–  Press key.
 
Channel  10  Adaptation   1           ->
                   (- ↑ ↓-)             
Readout on display:
–  Enter the residual value using the keypad, to do so fill in "0" as the first digits.
Example:
Residual value: 1000 km
Entry value: 00001
 
Channel  10        Adaptation         0
Enter adaptation value  XXXXX
Readout on display:
–  Confirm the entry with key Q.
 
Channel  10         Adaptation      0  Q
Enter adaptation value   00001    
Readout on display:
–  Confirm the entry with key Q.
 
Channel  10        Adaptation      1   Q
                           (- ↑   ↓-)   
Readout on display:
–  Confirm the entry with key Q.
 
Channel  10        Adaptation      1   Q
Store changed value?
Readout on display:
–  End the adaptation of the SID with the key .
 
Channel  10        Adaptation      1  ->
Changed value stored
Readout on display:
SID residual value for service inspection (distance)
The number of km which are left to drive before the next service inspection is required, can be entered with this channel if the dash panel insert is replaced.
–  Enter 11.
–  Confirm the entry with key Q.
 
Vehicle system test               HELP
Select function XX
Readout on display: the remaining kilometres until the inspection are displayed (5 is still 5000 km in our example)
–  Press key.
 
Channel  11   Adaptation  5           ->
                       (- ↑ ↓-)         
Readout on display:
–  Enter the residual value using the keypad, to do so fill in "0" as the first digits.
Example:
Residual value: 5000 km
Entry value: 00005
 
Channel  11        Adaptation         0
Enter adaptation value  XXXXX
Readout on display:
–  Confirm the entry with key Q.
 
Channel  11     Adaptation       0     Q
Enter adaptation value   00005
Readout on display:
–  Confirm the entry with key Q.
 
Channel  11    Adaptation  5           Q
                     (- ↑ ↓-)           
Readout on display:
–  Confirm the entry with key Q.
 
Channel  11        Adaptation      5   Q
Store changed value?
Readout on display:
–  End the adaptation of the SID with the key .
 
Channel  11        Adaptation      5  ->
Changed value stored
Readout on display:
SID residual value for service inspection (time)
The remaining time in days before the next service inspection is required, can be entered with this function if the dash panel insert is replaced.
–  Enter 12.
–  Confirm the entry with key Q.
 
Vehicle system test               HELP
Select function XX
Readout on display:
The remaining time in days before the inspection is displayed (11 is still 110 days in our example).
–  Press key.
 
Channel  12        Adaptation      11  ->
                     (- ↑ ↓-)           
Readout on display:
–  Enter the residual value using the keypad, to do so fill in "0" as the first digits.
Example:
Residual value: 110 days
Entry value: 00011
 
Channel  12    Adaptation        0      
Enter adaptation value  XXXXX
Readout on display:
–  Confirm the entry with key Q.
 
Channel  12  Adaptation         0      Q
Enter adaptation value   00011
Readout on display:
–  Confirm the entry with key Q.
 
Channel  12  Adaptation   11           Q
                     (- ↑ ↓-)           
Readout on display:
–  Confirm the entry with key Q.
 
Channel  12  Adaptation   11           Q
Store changed value?
Readout on display:
–  End the adaptation of the SID with the key .
 
Channel  12  Adaptation   11          ->
Changed value stored
Readout on display:
Adjustment of the fuel tank sender characteristic curve
The resistance characteristic curve of the fuel tank sender can be moved with this function in order to correct, if necessary, an inclined fuel tank sender.
–  Enter 30.
–  Confirm the entry with key Q.
 
Vehicle system test               HELP
Select function XX
Readout on display: the adaptation value is displayed, 128 in our example.
  Note
t  The adjustment value 128 is the average fuel tank sender characteristic curve set at the factory.
t  The resistance value of the fuel tank sender characteristic curve can be changed by ± 8 W to the adaptation value of 120 ... 136.
–  Press key.
 
Channel  30        Adaptation    128  ->
                   (- ↑   ↓-)           
Readout on display:
–  Enter the adaptation value using the keypad, to do so fill in "0" as the first digits, for example 132.
 
Channel  30        Adaptation       128
Enter adaptation value  XXXXX
Readout on display:
–  Confirm the entry with key Q.
 
Channel  30        Adaptation      128 Q
Enter adjustment value   00132    
Readout on display:
–  Confirm the entry with key Q.
 
Channel  30    Adaptation   132        Q
                       (- ↑ ↓-)         
Readout on display:
–  Confirm the entry with key Q.
 
Channel  30        Adaptation  132     Q
Store changed value?
Readout on display:
–  End the adaptation of the fuel tank sender characteristic curve with the key .
 
Channel  30   Adaptation  132         ->
Changed value stored
Readout on display:
 
Vehicle system test               HELP
Select function XX                        

Input values when changing the dash panel insert > < Adjustment