| Remove cap and belt pulley of AC generator with polygon-head adapter -MP 1-309-. |
Removing: turn the generator shaft to the right. |
The installation of the belt pulley of AC generator occurs in the reverse order of removal. |
Installing: turn the generator shaft to the left. Tightening torque: 80 Nm |
|
|
|