skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Parts of the refrigerant circuit > < Operation of the air conditioning system
Structure of the refrigerant circuit
Structure of the refrigerant circuit
  Note
All air conditioning components marked * as well as all refrigerant hoses and refrigerant lines must be repaired or replaced in service centres, as the refrigerant must first be drained off at a service position.
HP = High-pressure side
LP = Low-pressure side
   
1 - Oil drain plug*
2 - Magnetic coupling -N25-
3 - Compressor*
4 - Pressure relief valve*
5 - Condenser*
6 - Fluid container with desiccator*
7 - Exhaust, filler and measurement valve*
  Note
High-pressure side
8 - Cap
9 - Connection with valve*
10 - Air conditioner pressure switch -F129- or high pressure sensor -G65-
11 - Expansion valve*
12 - Evaporator*
13 - Cap
14 - Exhaust, filler and measurement valve*
q   Low-pressure side
15 - Pre-cubic contents*

   

Parts of the refrigerant circuit > < Operation of the air conditioning system