General instructions for refrigerant circuit > < O-ring seals
Work procedure before operating the air conditioning system after a repair
Work procedure before operating the air conditioning system after a repair
–  Turn the compressor on the clutch or the belt pulley of the magnetic coupling about 10 revolutions by hand.
–  Start the engine with the air conditioning system deactivated (air conditioner magnetic coupling -N25- and regulating valve for compressor of air conditioning system -N280- are not activated).
–  After the idling speed has stabilised, switch on the AC compressor and operate it for at least 10 minutes at idle speed and at maximum refrigerating capacity.
   

General instructions for refrigerant circuit > < O-ring seals