Operate the air conditioning system after filling |
Note If the AC compressor was removed, the free wheel must be turned by hand approx. 10 turns on the V-ribbed belt pulley before it is first put into service. This prevents that no damage occurs after switching on the air conditioning system for the first time as a result of fluid hammer in the AC compressor (if oil is present in the cylinder of the AC compressor, it is pressed out when turning). |
–
| Start the engine with the AC compressor switched off (version with magnetic coupling). |
–
| Set the AC compressor to the lowest possible performance; operating mode „Econ“ or A/C off (version without magnetic coupling with regulating valve). |
–
| Wait until the idling speed has stabilised. |
–
| Switch on the AC compressor and operate the system for at least 2 minutes at idle speed. |
–
| If necessary, check the pressures in the refrigerant circuit with the A/C service station. |
–
| Release the handwheel on the quick-coupling adapter. |
–
| Remove the filling hoses from the refrigerant circuit. |
–
| Screw on the protective caps once again. |
|
|
|