Fill refrigerant into the reservoir (filling cylinder or reservoir bottle) of the A/C service station > < Fill the refrigerant circuit with the A/C service station
Operate the air conditioning system after filling
Operate the air conditioning system after filling
  Note
If the AC compressor was removed, the free wheel must be turned by hand approx. 10 turns on the V-ribbed belt pulley before it is first put into service. This prevents that no damage occurs after switching on the air conditioning system for the first time as a result of fluid hammer in the AC compressor (if oil is present in the cylinder of the AC compressor, it is pressed out when turning).
–  Start the engine with the AC compressor switched off (version with magnetic coupling).
–  Set the AC compressor to the lowest possible performance; operating mode „Econ“ or A/C off (version without magnetic coupling with regulating valve).
–  Wait until the idling speed has stabilised.
–  Switch on the AC compressor and operate the system for at least 2 minutes at idle speed.
–  If necessary, check the pressures in the refrigerant circuit with the A/C service station.
–  Switch off engine.
–  Release the handwheel on the quick-coupling adapter.
–  Remove the filling hoses from the refrigerant circuit.
–  Screw on the protective caps once again.
   

Fill refrigerant into the reservoir (filling cylinder or reservoir bottle) of the A/C service station > < Fill the refrigerant circuit with the A/C service station