Roomster
Refrigerant oil |
As refrigerant oil is strongly hygroscopic (it absorbs humidity), protect open cans against penetrating humidity and immediately seal tight after use. |
Note
t | Refrigerant oils from the containers which were opened for a longer period of time, cannot be used. |
t | Because of its chemical properties, refrigerant oil must not be disposed of with engine oil or gearbox oil. The refrigerant oil must be disposed of as oil of unknown origin. |
t | The total volume of refrigerant oil is contained in the spare part-compressor. |
Manufacturer | Part number of AC compressor | Filling capacity | Part number of refrigerant oil |
Denso | 6Q0 820 808 D,E,F,G | 80 ± 10 cm3 | G 052 300 A2 |
1K0 820 808 A | 90 ± 10 cm3 | ||
1K0 820 859 T | 90 ± 10 cm3 | ||
Delphi | 5N0 820 803 A,C | 110 ± 10 cm3 | G 052 154 A2 |
Oil distribution | ||||
The oil, which before the first activation of the air conditioning system was located in the compressor's oil pan, is distributed as follows in the refrigerant circuit: | ||||
| approx. 50 % | |||
| approx. 10 % | |||
| approx. 10 % | |||
| approx. 20 % | |||
| approx. 10 % |