subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

With ABS|Page 3322 > < With ABS|Page 3320
Page 9
background image

^

A list of the support data is shown in the following table.

NOTE: For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.

CLEAR MEMORY MODE
1. On the <<Main Menu,, display screen, select {2. Each System Check} and press the <<YES>> key. 
2. On the <<System Select Menu>> display screen, select {Brake System} and press the <<YES>> key. 
3. Press the <<YES>> key after the engine type is displayed.
4. On the <<Brake Control Diagnosis>> display screen, select {Clear Memory} and press the <<YES>> key.
5. When 'Done' and turn ignition switch OFF' are shown on the display screen, turn the Subaru Select Monitor and ignition switch to OFF.

NOTE: For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.

FUNCTION CHECK

Without Subaru Select Monitor

Clear Memory Mode

OPERATION

WITHOUT SUBARU SELECT MONITOR

With ABS|Page 3322 > < With ABS|Page 3320