Thermoprotector - Service Procedure|Page 3612 > < Compressor Speed Sensor, HVAC|Locations
Page 1
background image

Thermal Limiting Fuse: Technical Service Bulletins
Thermoprotector - Service Procedure

NUMBER

10-58-90 (10-59-90)

DATE

05-30-90

APPLICABILITY

ALL L SERIES MODELS WITH FACTORY OR
ACCESSORY PANASONIC AIR CONDITIONING

SUBJECT:

THERMOPROTECTOR SERVICE PROCEDURE

This bulletin has been updated by TSB #105990, 7/6/90  (added to the end of this TSB). This bulletin is to be used as additional information for Section
4-7 of the 1985 to 1990 L Series and Loyale Genuine Subaru Service Manuals.

PANASONIC A/C TROUBLESHOOTING

Use the following manufacturer recommendations for diagnosing and servicing the thermoprotector.

THERMOPROTECTOR SERVICE PRECAUTION:

Never attempt to service the compressor thermoprotector without first completely discharging the A/C system. High side pressure is in contact with the
thermoprotector internal surfaces. Removal without discharging the A/C system may cause an extreme safety hazard.

THERMOPROTECTOR DIAGNOSIS AND SERVICE PROCEDURE:

DIAGNOSIS

Check that continuity across thermoprotector circuit is open when temperature is greater than 330~ F, R = infinite Ohms.

REPLACEMENT PROCEDURES

1.

Discharge A/C system.

Important Note:
Various R-12 reclamation procedures are currently being studied by the federal and state governments and acceptance of those procedures may
result in a prohibition against the release of R-12 into the atmosphere. Venting R-12 into the atmosphere depletes the earth's ozone layer. For that
reason, we strongly recommend use of a refrigerant reclamation station. If federal or state regulations are adopted prohibiting the discharge of R-12
into the atmosphere, a refrigerant reclamation station must be used.

2.

Remove snap-ring and thermoprotector.

3.

Clean sealing surfaces.

4.

Lubricate new O-ring, replace thermoprotector and snap-ring.

5.

Evacuate and recharge A/C system, refer to charging instructions.

6.

Leak check during operation.
NUMBER

10-59-90

DATE

07-06-90

APPLICABILITY

ALL L SERIES MODELS WITH FACTORY OR

ACCESSORY PANASONIC (MATSUSHITA) AIR CONDITIONING