SUBJECT:

THERMOPROTECTOR TESTING PROCEDURE CLARIFICATION

THIS BULLETIN IS TO BE USED AS AN ADDENDUM TO SERVICE BULLETIN 10-58-90 DATED 05-30-90

THERMOPROTECTOR DIAGNOSIS AND SERVICE PROCEDURE CLARIFICATION:

THERMOPROTECTOR FUNCTION (DEFINITION):

The thermoprotector and circuit is designed to open the compressor clutch circuit when the compressor head temperature reaches or exceeds 330~F.

THERMOPROTECTOR'S SERVICE PRECAUTION:

Never attempt to service the compressor's thermoprotector without first completely discharging the A/C system. High side pressure is in contact with the
thermoprotector's internal surfaces. Removal without discharging the A/C system may cause an extreme safety hazard.

THERMOPROTECTOR TESTING:

The thermoprotector circuit must have continuity at temperatures below 330~F. The continuity test can be performed with the A/C system off, see Figure
1.

^

Locate the thermoprotector connector and disconnect the thermoprotector from the wiring harness.

^

Using a volt-ohmmeter or continuity test light, measure or test for continuity across the two thermoprotector wiring connector terminals

^

If the circuit is open or no continuity (ohmmeter shows infinity) the clutch will not engage the A/C system, the thermoprotector must be
replaced.

Follow the replacement procedure in Service Bulletin 10-58-90 dated 05-30-90.

Restraint Systems > < Thermoprotector - Service Procedure