2. LH SIDE 

Install in the reverse order of removal.

NOTE: 
^

Use anew gasket. Apply liquid gasket to variable valve lift diagnosis oil pressure switch threads. 

^

Install the oil switching solenoid valve to the holder, then install it to the cylinder head.

Tightening torque: 

T1 8 N-m (0.8 kgf-m, 5.9 ft-lb)
T2 10 N-m (1.0 kgf-m, 7.4 ft-lb)
T3 17 N-m (1.7 kgf-m, 12.5 ft-lb)

Liquid gasket THREE BOND 1324 (Part No. 004403042)

Engine, Cooling and Exhaust > Engine > Actuators and Solenoids - Engine > Variable Valve Timing Solenoid > Component Information > Service and Repair > Page 1200