subaru Workshop Repair Guides

Subaru Workshop Service and Repair Manuals

Procedures|Page 4400 > < A/T - Inhibitor Switch Cover/Splash Fin Availability|Page 4397
Page 1
background image

Neutral Safety Switch: Procedures

INSPECTION 

When the driving condition or starter motor operation is improper, first check the shift linkage for improper operation. If the shift linkage is
functioning properly, check the inhibitor switch.

1) Disconnect the inhibitor switch connector.
2) Check continuity in inhibitor switch circuits with the select lever moved to each position.

NOTE:  
^

Also check that there is no continuity in the ignition circuit when the select lever is in the "R" and "D" ranges.

^

If the inhibitor switch does not operate, check for poor contact of the connector on transmission side.

3) Check that there is continuity at equal points when the select lever is turned 1.5° in both directions from the "N" range.
If there is continuity in only one direction or in other points, adjust the inhibitor switch. 

4) Repeat the above inspection in other gear ranges. If there are abnormalities, adjust the select cable. 

Procedures|Page 4400 > < A/T - Inhibitor Switch Cover/Splash Fin Availability|Page 4397