Refrigerant Oil: Service and Repair

Maintenance of Oil Quantity in Compressor

The oil in the compressor circulates through the system with the refrigerant. Add oil to compressor when replacing any component or after a large
refrigerant leakage has occurred. It is important to maintain the specified amount. If oil quantity is not maintained properly, the following malfunctions
may result:

-

Lack of oil: May lead to a seized compressor

-

Excessive oil: Inadequate cooling (thermal exchange interference)

OIL

SUZUKI approved A/C System Oil Type R or equivalent

CHECKING AND ADJUSTING

CAUTION:  If excessive oil leakage is noted, do not perform the oil return operation.

Start the engine and set the following conditions:

Test Condition

-

Engine speed: Idling to 1,200 rpm

-

A/C switch: On

-

Blower fan speed: Max. position

-

Temp. control: Optional [Set so that intake air temperature is 25 degree to 30 degree C (77 degree to 86 degree F)]

-

Perform oil return operation for about ten minutes

Adjust the oil quantity according to the following table.

Oil Adjusting Procedure for Components Replacement Except Compressor

After replacing any of the following major components, add the correct amount of oil to the system.

Amount of Oil to be Added

Oil Adjustment Procedure for Compressor Replacement

Refrigerant Oil|Capacity Specifications|Page 4104 > < Refrigerant Oil|Capacity Specifications|Page 4102