suzuki Workshop Repair Guides

Suzuki Workshop Service and Repair Manuals

Blower Case Assembly Replacement|Page 14628 > < Blower Case Assembly Replacement|Page 14626
Page 1
background image

Housing Assembly HVAC: Service and Repair
HVAC Module Assembly Replacement

HVAC Module Assembly Replacement

Special Tool

J 39400-A Halogen Leak Detector

1. Disable the Supplemental Inflatable Restraints (SIR) system. Refer to [SIR Disabling and Enabling].
2. Recover the refrigerant. Refer to [Refrigerant Recovery and Recharging].

3. Drain the engine coolant. Refer to [Draining and Filling Cooling System (LY7 GE 47716 Fill)] [Draining and Filling Cooling System (LY7 Static

Fill)].

4. Remove the evaporator outlet hose and liquid line nut from the thermal expansion valve (TXV).
5. Remove the evaporator outlet hose from the TXV.
6. Remove and discard the sealing washer from the evaporator outlet hose. Refer to [Sealing Washer Replacement].
7. Remove the evaporator outlet hose and liquid line from the TXV.
8. Remove and discard the sealing washer from the liquid line. Refer to [Sealing Washer Replacement].

Blower Case Assembly Replacement|Page 14628 > < Blower Case Assembly Replacement|Page 14626