1. Remove heater control plate.

A. Pull off the heater control knobs.
B. With A/C: Pry off the A/C switch.
C. Using a screwdriver, pry out the heater control plate.

HINT:  Tape the screwdriver tip before use.

D. With Clock: Disconnect the connector.

2. Remove the 2 screws and hang the heater control unit.
3. Remove the illumination light from the A/C control assembly.
4. Using a screwdriver, pry loose the clip and push out the blower speed control switch to the rear of the A/C control.

Reverse procedure to reinstall.