4 Runner 2WD L4-2693cc 2.7L DOHC MFI (1997)
3. Measure torque converter clutch sleeve runout
Temporarily mount the torque converter clutch to the drive plate. Set up a dial indicator.
Maximum runout: 0.30 mm (0.0118 inch)
If runout is not within the specification, try to correct by reorienting the installation of the torque converter clutch.
HINT: Mark the position of the torque converter clutch to ensure correct installation.