Lamp Control Module: Testing and Inspection

INSPECT INTEGRATION RELAY OPERATION 

Key Unlock Warning System:

(a)  Connect the positive (+) lead from the battery to terminal 12.
(b) Connect the negative (-) lead from the battery to terminals 5, 7 and 10.
(c)  Check the chime sounds.

(d) Disconnect the negative (-) lead from the battery to terminal 10.
(e)  Check that the chime stops sounding.

(f)  Connect the negative (-) lead from the battery to terminal 10.
(g)  Connect the positive (+) lead from the battery to terminal 6.
(h)  Check that the chime stops sounding.

If operation is not as specified, replace the relay.

INSPECT INTEGRATION RELAY CIRCUIT