Leak Detection Sensor: Testing and Inspection

1. INSPECT POWER SOURCE VOLTAGE OF VAPOR PRESSURE SENSOR

-

Disconnect the vapor pressure sensor connector.

-

Turn the ignition switch ON.

-

Using a voltmeter, measure the voltage between connector terminals VC and E2 of the wiring harness side.

Voltage: 4.5 - 5.5 V. 

-

Turn the ignition switch to LOCK.

-

Reconnect the vapor pressure sensor connection

2. INSPECT POWER OUTPUT OF VAPOR PRESSURE SENSOR

-

Turn the ignition switch ON.

-

Disconnect the vacuum hose from the vapor pressure sensor.

-

Connect a voltmeter to terminals PTNK and E2 of the ECM, and measure the output voltage under the following conditions:
-

Apply vacuum (2.0 kPa, 15 mmHg, 0.59 in.Hg) to the vapor pressure sensor.

Voltage: 1.3 - 2.1 V 

-

Release the vacuum from the vapor pressure sensor. 

Voltage: 3.0 - 3.6 V 

-

Apply pressure (1.5 kPa, 15 gf/sq.cm, 0.22 psi to the vapor pressure sensor. 

Voltage: 4.2 - 4.8 V 

-

Reconnect the vacuum hose to the vapor pressure sensor.