toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Leak Detection Sensor, Evaporative System|Specifications|Page 3053 > < Emissions - Charcoal Canister Standardized|Page 3049
Page 1
background image

Leak Detection Sensor: Specifications

Voltage at connector: (sensor disconnected)

VC - E2 .................................................................................................................................................................................................  4.5 - 5.5 Volts

Voltage at sensor (sensor connected, vacuum/pressure applied)

None ......................................................................................................................................................................................................  2.9 - 3.7 Volts
2.0 kpa, 15 mm Hg, 0.59 in.Hg .............................................................................................................................................................  1.3 - 2.1 Volts
1.5 kpa, 15 gf/cm2, 0.22 psi ..................................................................................................................................................................  4.2 - 4.8 Volts

Leak Detection Sensor, Evaporative System|Specifications|Page 3053 > < Emissions - Charcoal Canister Standardized|Page 3049