Avalon V6-3.0L (1MZ-FE) (1996)
Leak Detection Sensor: Specifications
Voltage at connector: (sensor disconnected)
VC - E2 ................................................................................................................................................................................................. 4.5 - 5.5 Volts
Voltage at sensor (sensor connected, vacuum/pressure applied)
None ...................................................................................................................................................................................................... 2.9 - 3.7 Volts
2.0 kpa, 15 mm Hg, 0.59 in.Hg ............................................................................................................................................................. 1.3 - 2.1 Volts
1.5 kpa, 15 gf/cm2, 0.22 psi .................................................................................................................................................................. 4.2 - 4.8 Volts