Avalon V6-3.0L (1MZ-FE) (1996)
-
Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance: At 2O°C (68°F): 11 - 16 ohms
-
If the resistance is not as specified, replace the sensor.
Torque: 44 Nm (440 kgf.cm. 31 ft.lb)
-
Reconnect the oxygen sensor connector.
-
Floor shift: Reinstall the floor carpet.
-
Column shift: Reinstall the passenger's seat.
SEE ALSO:
Refer to Trouble Code Descriptions for a listing of Trouble Code Charts containing information about heated oxygen sensor testing.
See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble Code Descriptions