Avalon V6-3.5L (2GR-FE) (2006)
Brake Fluid Level Sensor/Switch: Testing and Inspection
INSPECT BRAKE FLUID LEVEL WARNING SWITCH
a. Remove the reservoir tank cap and strainer.
b. Disconnect the connector.
c. Measure the resistance between the terminals.
Standard:
Float up (switch off): 10 kOhms or higher
d. Use a syphon, etc. to take fluid out of the reservoir tank.
e. Measure the resistance between the terminals.
Standard:
Float down (switch on): Below 1 Ohm
f.
Pour the fluid back in the reservoir tank.