Avalon XL V6-3.0L (1MZ-FE) (1997)
Expansion Valve: Testing and Inspection
1. CHECK QUANTITY OF GAS DURING REFRIGERATION CYCLE
2. INSTALL MANIFOLD GAUGE SET
See: Service and Repair/Manifold Gauge Installation/Removal
3. RUN ENGINE
Run the engine at 1,500 rpm for at least 5 minutes.
Then check that the high pressure reading is 1.37 - 1.53 MPa (14 - 16 kg/Sq.cm, 199 - 228 psi).
4. CHECK EXPANSION VALVE
If the expansion valve is faulty, the low pressure reading will drop to 0 kPa (0 kg/Sq.cm, 0 psi).
HINT: When the low pressure drops to 0 kPa (0 kg/ cm2, 0 psi), feel the receiver's IN and OUT sides for zero temperature difference.