Ignition Cable: Testing and Inspection
HIGH-TENSION CORDS INSPECTION
1. REMOVE V-BANK COVER
2. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS
(a) Using needle-nose pliers, disconnect the cord clamp from the engine wire protector.
(b) Disconnect the high - tension cords at the rubber boot. Do not pull on the cords.
NOTICE: Pulling on or bending the cords may damage the conductor inside.
(c) Disconnect the high-tension cords from the clamp.
3. DISCONNECT HIGH-TENSION CORDS FROM IGNITION COILS
(a) Using a screwdriver, lift up the lock claw and disconnect the holder from the ignition coils.
(b) Disconnect the high-tension cord at the grommet. Do not pull on the cord.
NOTICE:
-
Pulling on or bending the cords may damage the conductor inside.
-
Do not wipe any of the oil from the grommet after the high-tension cord is disconnected.