Avalon XLS V6-3.0L (1MZ-FE) (1998)
Splice Point
K: Indicates a wiring Splice Point (Codes are "E" for the Engine Room, "I" for the Instrument Panel, and "B" for the Body).
The Location of Splice Point I 5 is indicated by the shaded section.
L: Page No.
Shielded Cable
M: Indicates a shielded cable.
N: Indicates a ground point.
Pin Number Of The Connector
O: Indicates the pin number of the connector. The numbering system is different for female and male connectors.
Example: Numbered in order
Numbered in order
from upper left to
from upper right to
lower right
lower left
The numbering system for the overall wiring diagram is the same as above.
P: When 2 parts both use one connector in common, the parts connector name used in the wire routing section is shown in square brackets [ ].