toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

HV Converter|Page 3530 > < HV Converter|Page 3528
Page 4
background image

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

CAUTION:  Wear insulated gloves.

b. Connect the wire harness with the 3 clamps.

CAUTION:  Wear insulated gloves.

c. Connect the AMD cable with the nut.

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

CAUTION:  Wear insulated gloves.

d. Connect the high voltage cable with the nut.

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

CAUTION:  Wear insulated gloves.

3. CONNECT HV RELAY ASSEMBLY

a. Connect the 5 connectors to the HV relay assembly.

CAUTION:  Wear insulated gloves.

NOTE:
-

Connect the wire wrapped with red tape to the terminal indicated by the "+" mark of the HV relay and the wire not wrapped with red tape
to the terminal indicated by the "-" mark of the HV battery.

-

Make sure that the connectors are engaged securely.

b. Connect the ground cable with the nut.

Torque: 8.0 N.m (82 kgf.cm, 71 in.lbf)

HV Converter|Page 3530 > < HV Converter|Page 3528