Camry L4-2.4L (2AZ-FXE) Hybrid (2007)
(b) Connect the probes of an ohmmeter to terminals 6 (CANH) and 14 (CANL) of the DLC3.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
OK -- CHECK FOR SHORT IN CAN BUS WIRES
NG -- Continue to next step.
3. CHECK FOR SHORT IN CAN BUS WIRES (NO. 1 CAN J/C BRANCH WIRE)
(a) Reconnect CAN main bus wire connector E42 to the No. 1 CAN J/C "A" side (with earth terminal).
(b) Connect the probes of an ohmmeter to terminals 6 (CANH) and 14 (CANL) of the DLC3.
(c) While observing the resistance value shown on the tester, disconnect connectors E44, E45, E46 and E63 from the No. 1 CAN J/C one by
one until the resistance becomes normal (between 54 and 69 Ohms).
HINT: Disconnect the branch wire connectors other than those of the DLC3.