toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 1626
Page 2
background image

exhaust gas).

-

Repeat the test 2 or 3 times.

-

Make sure that there is some refrigerant remaining in the refrigeration system.
When the compressor is off: approx. 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)

(c) Using a gas leak detector, check for leakage from the refrigerant lines.

(d) Bring the gas leak detector close to the drain hose with the detector's power off, and then turn the detector on.

-

After the blower motor has stopped, let the cooling unit stand for more than 15 minutes.

-

Bring the gas leak detector sensor under the drain hose.

-

When bringing the gas leak detector close to the drain hose, make sure that the gas leak detector does not react to volatile gases.
If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow testing.

(e) If a gas leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the gas leak detector sensor into

the unit and perform the test.

(f) Disconnect the pressure switch connector and leave it for approximately 20 minutes. Bring the gas leak detector close to the pressure switch

and perform the test.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 1626