Camry LE Sedan L4-2164cc 2.2L DOHC (5S-FE) MFI (2000)
Oxygen Sensor: Testing and Inspection
Heated Oxygen Sensor
COMPONENTS
INSPECTION
1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
a. Disconnect the oxygen sensor connector.
b. Using an ohmmeter, measure the resistance between terminals +B and HT
Resistance: 11 - 16 Ohms at 20° C (68° F)
-
If the resistance is not as specified, replace the sensor.
Torque: 44 Nm (450 kg.cm, 32 ft.lb)
c. Reconnect the oxygen sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSOR