Power Door Lock Relay: Testing and Inspection

Door lock signal:
INSPECT INTEGRATION RELAY (Type B) OPERATION

HINT:  When the relay circuit is as specified, inspect the door lock signal.

a. Connect the positive (+) lead from the voltmeter to terminal A12 and the negative (-) lead to terminal A25.
b. Set the door lock control switch to UNLOCK and check that the voltage rises from 0 V to battery positive voltage for approximately 0.2 seconds.

c. Reverse the polarity of the voltmeter leads.
d. Set the door lock control switch to LOCK and check that the voltage rises from 0 V to battery positive voltage for approximately 0.2 seconds.

If operation is not as specified, replace the relay.

Door lock signal:
INSPECT INTEGRATION RELAY (Type C) OPERATION

HINT:  When the relay circuit is as specified, inspect the door lock signal.

a. Connect the positive (+) lead from the voltmeter to terminal A6 and the negative (-) lead to terminal A7.
b. Set the door lock control switch to UNLOCK and check that the voltage rises from 0 V to battery positive voltage for approximately 0.2 seconds.

Power Door Lock Relay|Testing and Inspection|Page 14 > < Antitheft - Automatic Door Lock Feature Programming|Page 9