Refrigerant Pressure Sensor / Switch: Testing and Inspection

Check high pressure switch.

a. Install manifold gauge set.
b. Check the continuity between two terminals of the pressure switch when refrigerant pressure is less than approx. 12.5 kg/cm2 (178 psi, 1,226

kPa).

c. Check for no continuity between two terminals of the pressure switch when refrigerant pressure is more than approx. 15.5 kg/cm2 (22 psi,

1520 kPa).

If continuity is not as specified, replace the switch.

ON-VEHICLE INSPECTION

1. Disconnect connector of pressure switch.
2. Inspect pressure switch.

a. Install the manifold gauge set.
b. Observe the gauge reading.
c. Check the continuity between the two terminals of the pressure switch shown in the below.

If defective, replace the pressure switch.

3. Connect connector of pressure switch.

Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 2831 > < Refrigerant Pressure Sensor / Switch, HVAC|Locations