c. Inspect the No.2 cooling fan relay continuity.

1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay.

2. Check that there is continuity between terminals 3 and 4.

If there is no continuity, replace the relay.

3. Check that there is no continuity between terminals 3 and 5.

If there is continuity, replace the relay.

d. Inspect the No.2 cooling fan relay operation.

1. Apply battery positive voltage across terminals 1 and 2.
2. Using an ohmmeter, check that there is no continuity between terminals 3 and 4.

If there is continuity, replace the relay.

3. Check that there is continuity between terminals 3 and 5.

If there is no continuity, replace the relay.

e. Reinstall the No.2 cooling fan relay.
f.

Reinstall the relay box cover.

3. INSPECT NO.3 COOLING FAN RELAY

a. Remove the relay box cover.
b. Remove the No.3 cooling fan relay. (Marking: FAN No.3)

c. Inspect the No.3 cooling fan relay continuity.

1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay.