Camry Solara SLEV6 V6-3.0L (1MZ-FE) (2000)
5. CAULK LOCK PLATE
a. Lightly press SST against the lock plate in the order shown in the illustration. After repeating this a few times, fully caulk the lock plate by
squeezing the handle until stopped by the stopper plate.
SST 09230-01010
HINT:
^
Do not stake the areas protruding around the pipes, brackets or tank ribs.
^
The points shown in the rib sides and oil cooler near here cannot be staked with SST. Use pliers or similar object and be careful not to
damage the core plates.
b. Check the lock plate height (H) after completing the caulking.
Plate height (H): 7.4 - 7.8 mm (0.2959 - 0.3119 inch)