Camry Solara SLEV6 V6-3.0L (1MZ-FE) (2000)
Oxygen Sensor: Testing and Inspection
Air/Fuel Ratio Sensor
INSPECT HEATER RESISTANCE OF A/F SENSORS (Bank 1 sensor 1, Bank 2 Sensor 1)
a. Disconnect the A/F sensor connector.
b. Using an ohmmeter measure the resistance between terminals +B and HT.
Resistance:
At 20 °C (68 °F)
0.8 - 1.4 Ohms
At 800 °C (1,472 °F)
1.8 - 3.2 Ohms
If the resistance is not as specified, replace the sensor.
Torque: 44 Nm (440 kg.cm, 31 ft.lb)
c. Reconnect the A/F sensor connector.