toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < Evaporative Vapor Pressure Sensor|Locations|Page 2184
Page 2
background image

c. Using a voltmeter, measure the voltage between connector terminals VC and E2 of the wiring harness side.

Voltage: 4.5 - 5.5 Volt

d. Turn the ignition switch OFF.
e. Reconnect the vapor pressure sensor connector.

2. INSPECT POWER OUTPUT OF VAPOR PRESSURE SENSOR

a. Turn the ignition switch ON.

b. Disconnect the fuel hose from the vapor pressure sensor.

c. Connect a voltmeter to terminals PTNK and E2 of the ECM, and measure the output voltage under the following conditions:

1. Apply vacuum (2.0 kPa (15 mmHg, 0.59 in.Hg)) to the vapor pressure sensor.

Voltage: 1.3 - 2.1 Volt

2. Release the vacuum from the vapor pressure sensor.

Voltage: 3.0 - 3.6 Volt

3. Apply pressure (1.5 kPa (15 g/sq.cm, 0.22 psi)) to the vapor pressure sensor.

Voltage: 4.2 - 4.8 Volt

d. Turn the ignition switch OFF
e. Reconnect the fuel hose to the vapor pressure sensor.

Fuel Delivery and Air Induction > < Evaporative Vapor Pressure Sensor|Locations|Page 2184