toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Distributor, Ignition > < California Vehicles
Page 1
background image

Ignition Cable: Testing and Inspection
Federal Vehicles

INSPECTION PROCEDURE

1. DISCONNECT HIGH-TENSION CORDS FROM SPARK PLUGS.

NOTE:  Disconnect the high - tension cords at the rubber boot. DO NOT pull on the cords. Pulling on or bending the cords may damage the
conductor Inside.

2. DISCONNECT HIGH-TENSION CORDS FROM DISTRIBUTOR CAP.

3. INSPECT HIGH-TENSION CORD RESISTANCE.

-

Using an ohmmeter measure the resistance. 

Maximum resistance: 25 k ohms per cord 

 

-

If the resistance is greater than maximum, check the terminals.

-

If necessary, replace the high - tension cord.

4. RECONNECT HIGH-TENSION CORDS TO DISTRIBUTOR CAP.
5. RECONNECT HIGH-TENSION CORDS TO SPARK PLUGS.

Distributor, Ignition > < California Vehicles