VSV for EVAP: Testing and Inspection

1. REMOVE VSV
2. INSPECT VSV

a. Inspect the VSV for open circuit.

Using an ohmmeter, check that there is continuity between the terminals.
Resistance: 30 - 34 Ohms at 20° C (68° F)
If there is no continuity, replace the VSV.

b. Inspect the VSV for ground.

Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.

c. Inspect the VSV operation.

1. Check that air dose not flow from ports E to F.

NOTE:  Never apply more than 93 kPa (0.95 kgf/sq cm, 13.5 psi) of pressure compressed air to the VSV.

2. Apply battery positive voltage across the terminals.
3. Check that air flows from ports E to F. It operation is not as specified, replace the VSV.