toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 1856 > < Refueling Vapor Cut Valve|Testing and Inspection
Page 1
background image

Positive Crankcase Ventilation Valve: Testing and Inspection

INSPECTION

1. REMOVE PCV VALVE

a. Disconnect the PCV hose from the PCV valve.
b. Remove the PCV valve.

PCV Testing

2. INSTALL CLEAN HOSE TO PCV VALVE
3. INSPECT PCV VALVE OPERATION

a. Blow air into the cylinder head side, and check that air passes through easily.

CAUTION:  Do not suck air through the valve. Petroleum substances inside the valve are harmful.

b. Blow air into the intake manifold side, and check that air passes through with difficulty.

If operation is not as specified, replace the PCV valve.

4. REMOVE CLEAN HOSE FROM PCV VALVE

Positive Crankcase Ventilation Valve|Testing and Inspection|Page 1856 > < Refueling Vapor Cut Valve|Testing and Inspection