toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Restraint Systems > < Vacuum Solenoid Valve HVAC|Specifications
Page 1
background image

Vacuum Solenoid Valve HVAC: Testing and Inspection

1. Remove Vacuum Switching Valve (VSV)

2. Check vacuum circuit continuity in VSV by blowing air into pipe.

a. Connect the VSV terminals to the battery terminals as shown.
b. Blow into pipe "A", and check that air comes out of pipe "B" but does not come out of filter "C".

c. Disconnect the battery.
d. Blow into pipe "A" and check that air comes out of filter "C" but does not come out of pipe "B".

If a problem is found, replace the VSV.

3. Check for short circuit using and ohmmeter, check that there is continuity between each terminal and the VSV body.

If a short circuit is found, repair or replace the VSV.

4. Check for open circuit using an ohmmeter, measure the resistance between the two terminals of the VSV.

Specified resistance: 38 - 43 Ohms at 2O°C (68°F). If resistance value is not as specified, replace the VSV.

Restraint Systems > < Vacuum Solenoid Valve HVAC|Specifications