c. Inspect the No. 3 cooling fan relay continuity.

1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.

If there is no continuity, replace the relay.

2. Check that there is no continuity between terminals 3 and 5.

If there is continuity, replace the relay.

d. Inspect the No. 3 cooling fan relay operation.

1. Apply battery positive voltage across terminals 1 and 2.
2. Using an ohmmeter, check that there is continuity between terminals 3 and 5.

If there is no continuity, replace the relay.

e. Reinstall the No. 3 cooling fan relay.
f.

Reinstall the relay box cover.

1. REMOVE COOLING FAN RELAY NO. 2 FROM ENGINE ROOM JIB

2. REMOVE COOLING FAN RELAY NO.3 FROM ENGINE ROOM J/B