toyota Workshop Repair Guides

Toyota Workshop Service and Repair Manuals

Restraint Systems > < Low Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 2345
Page 1
background image

Vacuum Solenoid Valve HVAC: Testing and Inspection

Fig. 19 Vacuum switching valve test.

1.

Disconnect electrical connectors and vacuum hoses from valve.

2.

Check for vacuum circuit continuity between by connecting valve to a suitable 12 volt source as shown, Fig. 19.

3.

Blow into pipe F and ensure air comes from pipe E.

4.

Disconnect battery cables, then blow into pipe F and check that air comes from filter G, not pipe E.

5.

If air is not expelled as described, replace valve.

6.

Using a suitable ohmmeter, check for continuity between each terminal and valve body. If continuity is found, a short circuit is indicated and valve
should be replaced.

7.

Using a suitable ohmmeter, check the resistance between the two valve terminals. Resistance should be 38-44 ohms. If resistance is not as
specified, replace valve.

Restraint Systems > < Low Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 2345